Carbon Dioxide Quality Check (CDQC)

Carbon Dioxide is usually used in food & beverages industry to preserve the quality of food products and carbonization of beverages. 

Because of high demand of improved quality and purity of Carbon Dioxide (CO2), manufacturer must compulsorily install the impurity check analysers or quality check analysers. It is very challenging for analyser service providers & CO2 Manufacturers to calibrate these analysers for given impurity components.

Here, we at Bhoruka are constantly developing certified calibration gas standards prepared gravimetrically (ISO 6142) and analysed on very accurate Gas Chromatography.

Our Calibration gas Standards are widely used by CO2 manufacturer, system integrators & calibration service providers.

We offer all Types of calibration gases for CDQC analyser systems.

Calibration Gas Standards for Total Sulphur Analyzer
ComponentsConcentration (v/v) or (mol/mol)
Cal Gas 1Cal gas 2Cal Gas 3Cal Gas 4Cal Gas 5Cal gas 6
Hydrogen Sulphide100 to 200 PPB100 to 200 PPB1 ppm1 to 20 ppm––
Methyl Mercaptan––1 ppm–1 to 20 ppm–
Methyl Ethyl sulphide––1 ppm–––
Carbonyl sulphide––1 ppm––1 to 20 ppm
Carbon Disulfide––––––
Sulphur Dioxide––––––
Dimethyl Sulphide––––––
NitrogenBALANCE %–Balance %Balance %Balance %Balance %
Carbon Dioxide–BALANCE %––––
Calibration Gas Standards for Total Hydrocarbon (THC) in CO2
ComponentsConcentration (v/v) or (mol/mol)
Cal Gas 1Cal gas 2Cal Gas 3
Methane10 to 20 ppm20 to 80 ppm20 to 40 ppm
Ethane10 to 20 ppm––
Ethylene10 to 20 ppm––
Propane10 to 20 ppm–20 to 40 ppm
Propylene10 to 20 ppm––
N-Butane10 to 20 ppm––
Iso-Butane10 to 20 ppm––
N-Pentane10 to 20 ppm––
Iso-Pentane10 to 20 ppm––
1-butene10 to 20 ppm––
1-Pentene10 to 20 ppm––
NitrogenBalance %–Balance %
Carbon Dioxide–Balance %–
Calibration Gas Standards for Trace Aromatics & Oxygenates
ComponentsConcentration (v/v) or (mol/mol)
Cal Gas 1Cal gas 2Cal Gas 3
Acetaldehyde0.1 ppm1 to 2 ppm1 to 2 ppm
Methanol20 ppm5 to 10 ppm–
Ethanol10 ppm––
benzene1 ppm80 to 100 PPB80 to 100 PPB
Ethane1 ppm––
Ethylene1 ppm––
N-Butane1 ppm––
Propane1 ppm––
Propylene1 ppm––
P-xylene1 ppm––
Toluene1 ppm––
Methane5 ppm––
NitrogenBalance %Balance %Balance %
Calibration Gas Standards for Trace Oxygen
  • We can supply as low as 2 ppm O2 in CO2 or N2
  • Standard Calibration Gas for CDQC is 20 to 40 ppm Oxygen in Carbon Dioxide
  • The CO2 used will be free of HCs and Sulfides
Gas Standard for Zero Calibration of Total HCs/ Sulfides
  • Mainly High Pure Carbon dioxide is used for Zero Calibration
  • We supply High Purity Carbon Dioxide with traces of known impurities
  • Purity of Carbon dioxide (CO2) is 99.999%

High Pure Hydrogen (with <1 ppm THC) as Fuel Gas